CE means CE mark permitted by the European Committe for the Electromechanical Standarization
Ex inside the Hexagon means "Protection against the Explosions"
Underwriters Laboratory found that samples of this product met UL's safety requirements. These requirements are primarily based on UL's own published Standards for Safety.
Canadian regulations require electrical products to be certified. CSA International is recognized throughout Canada as the premier certification organization for electrical products. We are accredited by the Standards Council of Canada (SCC).
MSHA The Mine Safety and Health Administration is a program sponsored by the U.S. Department of Labor. The Approval and Certification Center approves and certifies certain mining products for use in underground coal and gassy underground metal mines.
Factory Mutual
AUS Australian Board of Approvals
The National Urban Search and Rescue (US&R) Response System

Specific Light Approvals

 
SUPER PELILITE #1800 (Cp: 10,000)
FM	Class I, II; Div 2; Group ABCD/G, T4
MSHA	10C-628-O
CSA	Class I; Div 2; Group ABCD, T3C 
Class II; Div 2; Group G
UL	Class I; Div 1; Group D, 
Class 1, Zone 1, Group IIA, T3
Ex (CE)	Ex II 3 G Ex N IIC T4

POCKET SABRE #1820 (Cp: 10,000)
FM	Class I, II, III; Div 2; Groups ABCD/FG, T4
UL	Class I; Div 1; Group D, T2D
Ex (CE)	Ex II 3 GD EEx nL IIC T5
CSA	Class I, II, III; Div 2; 
	Groups ABCD/FG, T3C

MITYLITE #1900 (Cp: 4,000)
FM	Class I; Div 2; Group ABCD, T3C
CSA	Class I; Div 2; Group ABCD, T3C 
Class II; Div 2; Group G
AUS	Ex884x Ex ia s T4 IIB IP65 Zone 0
Ex (CE)	Ex II 3 G Ex N IIC T4

MINI MITYLITE #1910 (Cp: 2,000)
Ex (CE)	Ex II 3 GD EEx nL IIC T5

L1 #1930 (Cp: 6,000)
Ex (CE)	Ex II 1 G EEx ia IIC T6 Tamb 
(Zone 0 version only)
UL	Class I; Div 1; Groups ABCD 
(INTRINSICALLY SAFE)

SUPER MITYLITE #1970 (Cp: 6,000)
CSA	Class I; Div 2; Group ABCD, T3C 
Class II; Div 2; Group G
UL	Class I; Div 1; Groups CD, T3C
Ex (CE)	Ex II 3G Ex N IIC T4
	
SUPER SABRELITE #2000 (Cp: 12,000)
FM	Class I, II; Div 2; Group ABCD/G,
T3C
MSHA	10C-629-2
CSA	Class I; Div 2; Group ABCD,T3C
Class II; Div 2; Group G
AUS	Zone O Ex s 11C T3 Aus Ex1053
UL	Class I, Div I, Group CD, T3C
Class I, Zone I, Group IIA, IIB,T3C
Ex (CE)	Ex II 3 G Ex N IIC T4
Ex (CE) Zone 1 	Ex II 2 G Eex e ib IIC T4
	
FLASHER #2120
Ex (CE)	Ex II 3 G EEx nL IIC T6
	
MINI FLASHER #2130
Ex (CE)	Ex II 3 G EEx nL IIC T6
	
TRACKER #2140 (Cp: 6,000)
(Non-Submersible Version)
FM	Class I, II, III; Div 2; Groups ABCD/
	FG, T4
UL	Class I; Div 1; Groups CD, T3C
	
TRACKER #2140 (Submersible Version)
UL	Class I; Div 1; Groups CD, T3C
Ex (CE)	Ex II 3 G EEx nL IIC T5
	
VERSABRITE #2250 (Cp: 6,000)
FM	Class I; Div 2; Group ABCD, T4
MSHA	10C-635-0
CSA	Class I; Div 2; Group ABCD, T3C
Ex (CE)	Ex II 3 G Ex N IIC T4
	
VERSABRITE II #2270 (Cp: 8,000)
FM	Class I: Div 2; Group ABCD, T3A
MSHA	10C-635-1
CSA	Class I; Div 2; Group ABCD, T3C
Ex (CE)	Ex II 3 G Ex N IIC T3
	
MITYLITE MAGNUM #2300 (Cp: 8,000) 
CSA	Class I; Div 2; Group ABCD, T3C
Class II; Div 2; Group G
FM	Class I; Div 2; Group ABCD, T3A
MSHA	10C -637- O
UL	Class I; Div 1; Group CD
Class I; Zone 1; Group IIB, T3C
Ex (CE)	Ex II 3 G Ex N IIC T3
	
MAGNUM PLUS 2AA #2340 (Cp: 8,000)
CSA	Class I; Div 2; Group ABCD, T3C
Class II; Div 2; Group FG
FM	Class I; Div 2; Groups ABCD, T3
MSHA	10C-637-O
UL	Class I; Div 1; Group CD
Class I; Zone 1; Group IIB, T3C
Ex (CE)	Ex II 3 G EEx nL IIC T4
	
BLACK KNIGHT M7 #2350 (Cp: 10,000) 
FM	Class I, II, III; Div 2; Group BCD/FG, T3C
Ex (CE)	Ex II 3 G EEx nL IIC T2
	
STEALTHLITE #2400 (Cp: 10,000)
FM	Class I; Div 2; Group ABCD, T3A
MSHA	10C-633-0
CSA	Class I; Div 2; Group ABCD, T3C
Class II; Div 2; Group G
UL	Class I; Div 1; Group D, Zone 1, IIA, T3
Ex (CE)	Ex II 3 G Ex N IIC T4
Ex (CE) Zone 1 	Ex II 2 G Eex e ib IIC T4
	
STEALTHLITE RECHARGEABLE #2450 (Cp: 15,000)
FM	Class I; Div 2, Group ABCD, T3
CSA 	Class I; Div 2; Group ABCD, T3C
Class II; Div 2; Group G 
Ex (CE)	Ex II 3 G Ex N IIC T4
	
HEADSUP LITE #2600 (Cp: Primary 10,000) 
(Cp: Back-up 6,000)
FM	Class I; Div 2; Group ABCD, T4A
CSA	Class II; Div 2: Group FG, Class III; Div 2, T3C
MSHA	10C-641-0
Ex (CE)	Ex II 3 G Ex N IIC T4
	
HEADSUP LITE #2610 (Cp: 3 LED 6,000) 
(Cp: 1 LED 6,000)
UL	Class I; Div 1; Group D, T1
	(INTRINSICALLY SAFE)
	
HEADSUP LITE #2620 (Cp: Xenon 10,000) 
(Cp: 3 LED 6,000)
UL	Class I; Div 1; Group ABCD, T3C
	
HEADSUP LITE #2640 (Cp: Halogen 10,000)
(Cp: 3 LED 6,000)
UL	Class I; Div 2; Group ABCD, T3
	
LASERFLEX 2D #3000 (Cp: 20,000)
Ex (CE)	Ex II 3 G Ex N IIC T3
	
BIG ED 4C #3700 (Cp: Primary 55,000)
(Cp: Back-up 45,000)
UL	Class I; Div 2; Groups ABCD, T2B
Ex (CE)	Ex II 3 G EEx nL IIC T4
	
BIG ED RECHARGEABLE #3750 (Cp: Primary 65,000)
(Cp: Back-up 45,000)
UL	Class I; Div 2; Groups ABCD, T2B
Ex (CE)	Ex II 3 G EEx nL IIC T2
	
KING PELICAN LITE #4000 (Cp: 100,000) 
FM	Class I; Div 2; Group CD, T1
CSA	Class I; Div 2; Group ABCD, T3C
Class II; Div 2; Group G
Ex (CE)	Ex II 3 G Ex N IIC T1

AQUA KING LITE #4100 (Cp: 100,000) 
Non-approved	

BRITELITE #5000 (Cp: 60,000) 
Ex (CE)	Ex II 3 G Ex N IIC T2

LASER PRO 4D #6000 (Cp: 60,000)
FM	Class I; Div 2, Group ABCD, T2A
CSA	Class I; Div 2; Group ABCD, T3C
Class II; Div 2; Group G
Ex (CE)	Ex II 3 G Ex N IIC T2

BLACK KNIGHT M13 #6050 (Cp: 80,000)
Non-approved 	

BLACK KNIGHT M9 #7050 (Cp: 20,000)
FM 	Class I; Div 2; Group ABCD, T1
Ex (CE) 	Ex II 3 G Ex nL IIC T1
Class I; Div 2; Group ABCD, T3C

M8 ALKALINE 3C #8030 (Cp: 12,000)
FM	Class I, Div 2; Group ABCD, T3C
Class II, III, Div 2, Gps FG T4 
UL	Class I; Div 1; Groups D, T3
Class I, Div 2, Gps ABCD T3
Class II, Div 2, Group G
Ex (CE)	Ex II 3 G EEx nL IIC T3

M10 ALKALINE 4C #8040 (Cp: 30,000)
FM	Class I; Div 2; Groups ABCD, T3A
Class II, III; Div 2 Groups FG, T4
UL	Class I; Div 1; Groups D, T3
Ex (CE)	Ex II 3 G EEx nL IIC T3
MSHA	10C  649 - O
CSA	Class I, II, III; Div 2; Groups ABCD/
FG, T3C

BLACK KNIGHT M11 #8050 (Cp: 40,000) 
CE	Approved using M10 Bulb 
*FM and CSA are recognized as cross-certified
*Cp: Candlepower
Ex: CENELEC ATEX
(EUROPEAN APPROVALS)

Back